Company record
Medtronic Perfusion Systems
0 FDA warning letters since 2023 and 24 recalls in the last 12 months.
Get an email the day FDA posts anything new about Medtronic Perfusion Systems.
Recalls
| Reported | Class | Firm | Product and reason |
|---|---|---|---|
| Aug 5 | Class II | Medtronic Perfusion Systems Device |
EOPA Elongated One-Piece Arterial Cannula DIL TIP 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77722 Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction. |
| Aug 5 | Class II | Medtronic Perfusion Systems Device |
EOPA 3D Arterial Cannula 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 78322 Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction. |
| Aug 5 | Class II | Medtronic Perfusion Systems Device |
EOPA 3D Arterial Cannula DIL TIP 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 78222 Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction. |
| Aug 5 | Class II | Medtronic Perfusion Systems Device |
EOPA Elongated One-Piece Arterial Cannula BLUNT 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77422 Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction. |
| Aug 5 | Class II | Medtronic Perfusion Systems Device |
EOPA Elongated One-Piece Arterial Cannula DIL TIP 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77622 Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction. |
| Aug 5 | Class II | Medtronic Perfusion Systems Device |
EOPA Elongated One-Piece Arterial Cannula BLUNT 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77522 Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction. |
| Jul 22 | Class II | Medtronic Perfusion Systems Device |
Medtronic Bio-Medicus Adult Cannula Kit, Product Number/CFN 96530-115; Cardiopulmonary bypass vascular cannula Medtronic received two complaints of loose foreign material confirmed as containing trace levels of blood. |
| Jul 22 | Class II | Medtronic Perfusion Systems Device |
Medtronic DLP One-Piece Pediatric Arterial Cannula, Product Number/CFN 77010; Cardiopulmonary bypass vascular cannula Medtronic received two complaints of loose foreign material confirmed as containing trace levels of blood. |
| Jul 1 | Class II | Medtronic Perfusion Systems Device |
Octopus Evolution AS Tissue Stabilizer, Model TS2500 During the manufacturing process, Medtronic personnel identified an assembly issue where the tubing was incorrectly positioned. The short tube was attached to the bottom of the canister, and the long tube was attached to the top, contrary to the intended design. |
| Jul 1 | Class II | Medtronic Perfusion Systems Device |
Octopus 4 Tissue Stabilizer, Model 29400 During the manufacturing process, Medtronic personnel identified an assembly issue where the tubing was incorrectly positioned. The short tube was attached to the bottom of the canister, and the long tube was attached to the top, contrary to the intended design. |
| Jul 1 | Class II | Medtronic Perfusion Systems Device |
Octopus Evolution Tissue Stabilizer, Model TS2000 During the manufacturing process, Medtronic personnel identified an assembly issue where the tubing was incorrectly positioned. The short tube was attached to the bottom of the canister, and the long tube was attached to the top, contrary to the intended design. |
| May 27 | Class II | Medtronic Perfusion Systems Device |
Medtronic DLP Retrograde Cannula Manual-Inflate Silicone Body 15FR, Model 94725; Cardiopulmonary bypass vascular catheter Certain lots of product have the potential for a sterile barrier breach. |
| May 27 | Class II | Medtronic Perfusion Systems Device |
Medtronic DLP Retrograde Cannula Manual-Inflate Silicone Body 13FR, Model 94913; Cardiopulmonary bypass vascular catheter Certain lots of product have the potential for a sterile barrier breach. |
| May 27 | Class II | Medtronic Perfusion Systems Device |
Medtronic DLP Retrograde Cannula Manual-Inflate Silicone Body 15FR, Model 94215T; Cardiopulmonary bypass vascular catheter Certain lots of product have the potential for a sterile barrier breach. |
| May 27 | Class II | Medtronic Perfusion Systems Device |
Medtronic GUNDRY Retrograde Cannula Manual-Inflate Silicone Body 13FR, Model 94113T; Cardiopulmonary bypass vascular catheter Certain lots of product have the potential for a sterile barrier breach. |
| May 27 | Class II | Medtronic Perfusion Systems Device |
Medtronic DLP Retrograde Cannula Manual-Inflate Silicone Body 15FR, Model 94665; Cardiopulmonary bypass vascular catheter Certain lots of product have the potential for a sterile barrier breach. |
| May 27 | Class II | Medtronic Perfusion Systems Device |
Medtronic DLP Retrograde Cannula Manual-Inflate Silicone Body 15FR, Model 94915; Cardiopulmonary bypass vascular catheter Certain lots of product have the potential for a sterile barrier breach. |
| May 27 | Class II | Medtronic Perfusion Systems Device |
Medtronic DLP Retrograde Cannula Manual-Inflate Silicone Body 15FR, Model 94965; Cardiopulmonary bypass vascular catheter Certain lots of product have the potential for a sterile barrier breach. |
| May 27 | Class II | Medtronic Perfusion Systems Device |
Medtronic DLP Retrograde Cannula Manual-Inflate Silicone Body 13FR, Model 94913L; Cardiopulmonary bypass vascular catheter Certain lots of product have the potential for a sterile barrier breach. |
| May 27 | Class II | Medtronic Perfusion Systems Device |
Medtronic GUNDRY Retrograde Cannula Manual-Inflate Silicone Body 15FR, Model 94115T; Cardiopulmonary bypass vascular catheter Certain lots of product have the potential for a sterile barrier breach. |
| Mar 4 | Class II | Medtronic Perfusion Systems Device |
Octopus Nuvo Tissue Stabilizer, disposable tissue stabilization system, Product Number TSMICS1 During the manufacturing, Medtronic personnel identified an assembly issue where the tubing was incorrectly positioned. The short tube was attached to the bottom of the canister, and the long tube was attached to the top, contrary to the intended design. |
| Nov 26, 2025 | Class II | Medtronic Perfusion Systems Device |
Medtronic HR-ACT (High Range Activated Clotting Time Cartridges), REF 402-03 Medtronic personnel observed trace amounts of dry blood on the external carton label and Instructions for Use (IFU) in five boxes of one lot of ACT Cartridges. |
| Nov 26, 2025 | Class II | Medtronic Perfusion Systems Device |
MC3 VitalFlow Console, REF 58100; Blood pump of ecmo As of August 6, 2025, Medtronic has received eleven reports of VitalFlow Consoles displaying an E70 error code during normal operation. When this occurs, the touch screen may become temporarily unresponsive and go blank for up to two minutes before recovering to full functionality. Importantly, the console continues to maintain set pump speed and function throughout. |
| Nov 19, 2025 | Class II | Medtronic Perfusion Systems Device |
Affinity NT Oxygenator, Oxygenator with Balance Biosurface and Uncoated Cardiotomy/Venous Reservoir, Product Number 541B Medtronic identified an Affinity NT Oxygenator unit with decreased CO2 gas transfer rates that did not meet performance requirements. |